DigiDesign MachineControl Especificaciones Pagina 41

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 98
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 40
Chapter 4: Using SYNC I/O 37
Serial Time Code with MachineControl
MachineControl-equipped Pro Tools systems
can utilize serial time code through either of the
SYNC I/O 9-pin ports. When using Machine-
Control with serial time code as the positional
reference, SYNC I/O must be locked to a Video
Reference. In this scenario, SYNC I/O is set to
Generate mode to indicate that positional infor-
mation is acquired by Pro Tools directly over the
9-pin cable, not through SYNC I/O. Refer to the
MachineControl Guide for complete serial time
code information.
Video and Clock Reference
If you have only a single video source, and since
SYNC I/O uses different video inputs depending
on configuration, you may want to follow the
wiring tip below to ensure that you have full
functionality in all configurations:
To work with a single video source:
1 Connect the video signal to Video Ref In.
2 Run a short BNC jumper cable from the Video
Ref Out connector to the Video In connector.
3 Connect the Video Out signal to the video in-
put of your “destination” VTR or video editing
system.
The choice of video connector also matters
when choosing a positional reference. For in-
stance, when SYNC I/O is in Generate mode and
Video is the current clock reference, the time
code reference for the generator is always from
the Video Ref In connector. However, if you se-
lect a positional reference other than Generate,
then the signal at the Video In connector is
used.
Digital Clock
To resolve SYNC I/O to external AES/EBU, Word
Clock, or Slave Clock:
From Pro Tools:
In the SYNC Setup section of the Session
Setup window, select the appropriate digital
clock reference from the Clock Reference pop-
up menu.
From the front panel:
1 Press the Clock Reference switch to select
DIGITAL.
2 Press Set, and use the Up or Down switches to
display Digital Reference (dI6 rEF).
3 Press Set again. The LED Time Code Display
displays the current digital reference, which will
be:
AES/EBU (AES-E8U)
– or –
•Word Clock (I CLOC)
4 Press Up or Down to select the digital clock
you want to use.
5 Press Set.
MachineControl also provides 9-Pin Deck
Emulation mode, but this mode is not sup-
ported through either of the SYNC I/O 9-pin
ports. See the Digidesign MachineControl
Guide for more information.
For more video signal information, refer to
“Video and VITC Signals” on page 67 in
Appendix A.
Vista de pagina 40